NXP Semiconductors /MIMXRT1011 /TEMPMON /TEMPSENSE0_SET

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as TEMPSENSE0_SET

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (POWER_UP)POWER_DOWN 0 (STOP)MEASURE_TEMP 0 (INVALID)FINISHED 0TEMP_CNT0ALARM_VALUE

MEASURE_TEMP=STOP, POWER_DOWN=POWER_UP, FINISHED=INVALID

Description

Tempsensor Control Register 0

Fields

POWER_DOWN

This bit powers down the temperature sensor.

0 (POWER_UP): Enable power to the temperature sensor.

1 (POWER_DOWN): Power down the temperature sensor.

MEASURE_TEMP

Starts the measurement process

0 (STOP): Do not start the measurement process.

1 (START): Start the measurement process.

FINISHED

Indicates that the latest temp is valid

0 (INVALID): Last measurement is not ready yet.

1 (VALID): Last measurement is valid.

TEMP_CNT

This bit field contains the last measured temperature count.

ALARM_VALUE

This bit field contains the temperature count (raw sensor output) that will generate a high alarm when TEMP_CNT is smaller than this field